Reach-in

Environmental Stress Chamber (AR series)

Available model with low GWP refrigerant R-449A and R-452A

ARSF and ARGF Chambers now available with low GWP refrigerent R-449A. ARL, ARU, ARS and ARG Chambers now availabe with low GWP refrigerant R-449A and R-452A.

Reduced temperature and humidity stabilization time

Temperature and humidity stabilization time have been greatly reduced by minimizing fluctuation as the chamber approaches set-point (under testing operation from room temperature to 85°C/85% rh).

Specimen temperature control function provides accurate testing

Uses a temperature control sensor to monitor and control the temperature of the specimen.

Supports heat loads up to 4500 W during temperature testing

Supports powered specimens, and can withstand up to 4500 W of heat load during temperature testing.

Meets International Standards

Designed to comply with major environmental test standards such as IEC60068 (2-1.2.3.14.30.38.78) or ISO16750-4 (5.3).

New Rapid-Rate Temperature Cycle Type

Chamber temperature change rates range from 10 to 18 K/min.

 

Environmental Stress Chamber (AR series) Model Comparison

ModelTemp.
Range
Hum.
Control
Hum.
Range
Heat up
Pull down
VolumeInside dimensions
in mm (WxHxD)
Outside dimensions
in mm (excl. projection)
ARS-0220-75 to +180°CYES10 to 98%-220 L700 x 800 x 400900 x 1742 x 1455
ARS-0390-75 to +180°CYES10 to 98%-390 L700 x 800 x 700900 x 1742 x 1705
ARS-0680-75 to +180°CYES10 to 98%-680 L850 x 1000 x 8001050 x 1955 x 1805
ARS-1100-75 to +180°CYES10 to 98%-1100 L1100 x 1000 x 10001300 x 1955 x 2005
ARL-0680-45 to +180°CYES10 to 98%-680 L850 x 1000 x 8001050 x 1955 x 1805
ARL-1100-45 to +180°CYES10 to 98%-1100 L1100 x 1000 x 10001300 x 1955 x 2005
ARSF-0250-10-70 to +180°CYES10 to 98%10 K/min.249 L600 x 830 x 500800 x 1703 x 1900
ARSF-0250-15-70 to +180°CYES10 to 98%18 K/min.249 L600 x 830 x 500800 x 1703 x 1900
ARSF-0400-10-70 to +180°CYES10 to 98%10 K/min.398 L600 x 830 x 800800 x 1703 x 2200
ARSF-0400-15-70 to +180°CYES10 to 98%15 K/min.398 L600 x 830 x 800800 x 1703 x 2200
ARSF-0800-10-70 to +180°CYES10 to 98%10 K/min.784 L1000 x 980 x 8001200 x 1853 x 2200
ARSF-0800-15-70 to +180°CYES10 to 98%15 K/min.784 L1000 x 980 x 8001200 x 1853 x 2200
ARG-0220-75 to +180°CNO--220 L700 x 800 x 400900 x 1742 x 1455
ARG-0390-75 to +180°CNO--390 L700 x 800 x 700900 x 1742 x 1705
ARG-0680-75 to +180°CNO--680 L850 x 1000 x 8001050 x 1955 x 1805
ARG-1100-75 to +180°CNO--1100 L1100 x 1000 x 10001300 x 1955 x 2005
ARU-0680-45 to +180°CNO--680 L850 x 1000 x 8001050 x 1955 x 1805
ARU-1100-45 to +180°CNO--1100 L1100 x 1000 x 10001300 x 1955 x 2005
ARGF-0250-10-70 to +180°CNO-10 K/min.249 L600 x 830 x 500800 x 1703 x 1900
ARGF-0250-15-70 to +180°CNO-18 K/min.249 L600 x 830 x 500800 x 1703 x 1900
ARGF-0400-10-70 to +180°CNO-10 K/min.398 L600 x 830 x 800800 x 1703 x 2200
ARGF-0400-15-70 to +180°CNO-15 K/min.398 L600 x 830 x 800800 x 1703 x 2200
ARGF-0800-10-70 to +180°CNO-10 K/min.784 L1000 x 980 x 8001200 x 1853 x 2200
ARGF-0800-15-70 to +180°CNO-15 K/min.784 L1000 x 980 x 8001200 x 1853 x 2200

Get more information

By submitting your request you agree to the processing of your data for the purpose of processing your request.
Data Protection Declaration and Revocation Notices