Walk-in

Walk-in Type Temperature (& Humidity) Chamber (E series)

Networking with new N-instrumentation

The tabbed user interface of the chamber instrumentation is designed to make operations for accessing to specific screens easier than ever.
An Ethernet (LAN) port is equipped as standard, which makes it possible to connect to and monitor the chamber operations from a device such as a PC, Smartphone or Tablet. As an option, a web browser can be used to communicate with the chamber to perform tasks such as modifying test conditions and even starting and stopping operations. Furthermore, the remote communication area can be expanded by connecting to an Intranet.

Remote monitoring

A web browser running on a computer connected to a chamber over an Ethernet connection can be used to monitor chamber running conditions.
Simply connect the chamber to a computer via LAN and set the IP address. No software or drivers are required.

Email alert

When an alarm is triggered, an email is sent to the registered PC or mobile address. *Connection to a mail server is required to use the email alert.

Backtrace function

When the chamber stops because of trouble, the operation status will be automatically recorded and saved. Just providing those data by email or USB memory stick, ESPEC can analyze the trouble and support the user.

Online diagnostics services

Diagnostics service is available using the backtrace data from the time of trouble.
Please send the backtrace data to ESPEC via email; we will analyze the cause of trouble and report the diagnosis back to you.
This service ensures accurately - performed diagnosis so that, in the case that repair work is required, appropriate troubleshooting  will be prescribed ensuring reduced testing downtime.
* Application page
www.espec.co.jp

Featuring a new high precision cooling system with greatly reduced power consumption (Patent pending)

Wide-range cooling control system, which is composed of an electronic expansion valve and a DC inverter, can widely and continuously vary refrigeration capacity.  Also a unique control method such as active map system is integrated, which can control the operation of multiple refrigerators by minimum power consumption.  This cooling system controls output and refrigeration capacity with high precision and achives both high performance and broad power savings. With automatic control, the system also demonstrates an even larger refrigeration capacity and quickly responds during repid and large heat-generationloards and during sharp drops in temperature and humidity.

Cross-output control reduces power equipment capacity (Japanese patent number 2928162) EBE, EBL, EBR

This is a large chamber with a wide test area, so a relatively high power capacity is required. Because operator and heater operate at the same time, the maximum energy flows when operations start. The cross-output control limits the maximum currents of the heater and the humidifier. It controls the currents by giving priority to the heater and adjusting the humidifier. It allows reducing the maximum current and thereby reducing the power equipment capacity. In addition, this feature can also be used to prevent dew condensation through delayed operation.

All-weather LED lights (Patent pending)

These newly-developed LED lights illuminate in the entire temperature and humidity control range, allowing energy savings, long life and excellent responsiveness. When turned on, LED lights bring brightness (approx. 2.5x), and also power consumption is reduced to approx. 1/5th compared to conventional incandescent lights.

Walk-in Type Temperature (& Humidity) Chamber (E series) Model comparison

ModelTemp.
Range
Hum.
Control
Hum.
Range
Pressure
range
VolumeInside dimensions
in mm (WxHxD)
Outside dimensions
in mm (excl. projection)
EBE Type 1-40 to +80°CYES10 to 95%rh-2m²1020 x 2100 x 19701791 x 2305 x 2100
EBE Type 2-40 to +80°CYES10 to 95%rh-3.9m²1970 x 2100 x 19702740 x 2305 x 2100
EBE Type 3-40 to +80°CYES10 to 95%rh-5.9m²3020 x 2100 x 19703790 x 2305 x 2100
EBE Type 4-40 to +80°CYES10 to 95%rh-8m²4070 x 2100 x 19704840 x 2305 x 2100
EBE Type 6-40 to +80°CYES10 to 95%rh-12.3m²4070 x 2100 x 30205295 x 2405 x 3150
EBE Type 8-40 to +80°CYES10 to 95%rh-16.6m²4070 x 2100 x 40705295 x 2405 x 4200
EBE Type 10-40 to +80°CYES10 to 95%rh-20.8m²5210 x 2100 x 40706345 x 2405 x 4200
EBE Type 12-40 to +80°CYES10 to 95%rh-25.1m²6170 x 2100 x 40707395 x 2405 x 4200
EBL Type 1-30 to +80°CYES10 to 95%rh-2m²1020 x 2100 x 19701791 x 2305 x 2100
EBL Type 2-30 to +80°CYES10 to 95%rh-3.9m²1970 x 2100 x 19702740 x 2305 x 2100
EBL Type 3-30 to +80°CYES10 to 95%rh-5.9m²3020 x 2100 x 19703790 x 2305 x 2100
EBL Type 4-30 to +80°CYES10 to 95%rh-8m²4070 x 2100 x 19704840 x 2305 x 2100
EBL Type 6-30 to +80°CYES10 to 95%rh-12.3m²4070 x 2100 x 30205295 x 2405 x 3150
EBL Type 8-30 to +80°CYES10 to 95%rh-16.6m²4070 x 2100 x 40705295 x 2405 x 4200
EBL Type 10-30 to +80°CYES10 to 95%rh-20.8m²5210 x 2100 x 40706345 x 2405 x 4200
EBL Type 12-30 to +80°CYES10 to 95%rh-25.1m²6170 x 2100 x 40707395 x 2405 x 4200
EBR Type 1-10 to +80°CYES20 to 95%rh-2m²1020 x 2100 x 19701791 x 2305 x 2100
EBR Type 2-10 to +80°CYES20 to 95%rh-3.9m²1970 x 2100 x 19702740 x 2305 x 2100
EBR Type 3-10 to +80°CYES20 to 95%rh-5.9m²3020 x 2100 x 19703790 x 2305 x 2100
EBR Type 4-10 to +80°CYES20 to 95%rh-8m²4070 x 2100 x 19704840 x 2305 x 2100
EBR Type 6-10 to +80°CYES20 to 95%rh-12.3m²4070 x 2100 x 30205295 x 2405 x 3150
EBR Type 8-10 to +80°CYES20 to 95%rh-16.6m²4070 x 2100 x 40705295 x 2405 x 4200
EBR Type 10-10 to +80°CYES20 to 95%rh-20.8m²5210 x 2100 x 40706345 x 2405 x 4200
EBR Type 12-10 to +80°CYES20 to 95%rh-25.1m²6170 x 2100 x 40707395 x 2405 x 4200
EBF Type 1-40 to +80°CNO--2m²1020 x 2100 x 19701791 x 2305 x 2100
EBF Type 2-40 to +80°CNO--3.9m²1970 x 2100 x 19702740 x 2305 x 2100
EBF Type 3-40 to +80°CNO--5.9m²3020 x 2100 x 19703790 x 2305 x 2100
EBF Type 4-40 to +80°CNO--8m²4070 x 2100 x 19704840 x 2305 x 2100
EBF Type 6-40 to +80°CNO--12.3m²4070 x 2100 x 30205295 x 2405 x 3150
EBF Type 8-40 to +80°CNO--16.6m²4070 x 2100 x 40705295 x 2405 x 4200
EBF Type 10-40 to +80°CNO--20.8m²5210 x 2100 x 40706345 x 2405 x 4200
EBF Type 12-40 to +80°CNO--25.1m²6170 x 2100 x 40707395 x 2405 x 4200
EBU Type 1-30 to +80°CNO--2m²1020 x 2100 x 19701791 x 2305 x 2100
EBU Type 2-30 to +80°CNO--3.9m²1970 x 2100 x 19702740 x 2305 x 2100
EBU Type 3-30 to +80°CNO--5.9m²3020 x 2100 x 19703790 x 2305 x 2100
EBU Type 4-30 to +80°CNO--8m²4070 x 2100 x 19704840 x 2305 x 2100
EBU Type 6-30 to +80°CNO--12.3m²4070 x 2100 x 30205295 x 2405 x 3150
EBU Type 8-30 to +80°CNO--16.6m²4070 x 2100 x 40705295 x 2405 x 4200
EBU Type 10-30 to +80°CNO--20.8m²5210 x 2100 x 40706345 x 2405 x 4200
EBU Type 12-30 to +80°CNO--25.1m²6170 x 2100 x 40707395 x 2405 x 4200
EBUU Type 1-10 to +80°CNO--2m²1020 x 2100 x 19701791 x 2305 x 2100
EBUU Type 2-10 to +80°CNO--3.9m²1970 x 2100 x 19702740 x 2305 x 2100
EBUU Type 3-10 to +80°CNO--5.9m²3020 x 2100 x 19703790 x 2305 x 2100
EBUU Type 4-10 to +80°CNO--8m²4070 x 2100 x 19704840 x 2305 x 2100
EBUU Type 6-10 to +80°CNO--12.3m²4070 x 2100 x 30205295 x 2405 x 3150
EBUU Type 8-10 to +80°CNO--16.6m²4070 x 2100 x 40705295 x 2405 x 4200
EBUU Type 10-10 to +80°CNO--20.8m²5210 x 2100 x 40706345 x 2405 x 4200
EBUU Type 12-10 to +80°CNO--25.1m²6170 x 2100 x 40707395 x 2405 x 4200

Get more information

By submitting your request you agree to the processing of your data for the purpose of processing your request.
Data Protection Declaration and Revocation Notices